There is a DA720 compatible DMX board in the system. This pragma file 
signals the RTMC software that there is a DA720 board present.

This board provides up to 48 channels of DMX control to a K48 system. 

K2001 systems do not usually need this card, since they already have 
built-in support for 16 channels of DMX on board.

Kuper systems already have software software support for interface to 
RTD's DA720, 8 channel digital-to-analog converter card. The DMX board 
mimics 6 DA720's to provide up to 48 channels of DMX. 

The Kuper "Patch Dac" and "Enable Dac" functions opeate with this board
in the same fashion that they operate with the DA720 cards.

As configured the DMX  board responds to addresses 
280, 290, 2a0, 2b0, 2c0, and 2d0

These addresses are mapped for the Kuper in file "dacaddr" as follows ...

Kup 1 - 8     DAC address 280-28f DMX channels 1 - 8    (D/A card #1)
Kup 9 - 16    DAC address 290-29f DMX channels 9 - 16   (D/A card #2)
Kup 17 - 24   DAC address 2a0-2af DMX channels 17 - 24  (D/A card #3)
Kup 25 - 32   DAC address 2b0-2bf DMX channels 25 - 32  (D/A card #4)  
Kup 33 - 40   DAC address 2c0-2cf DMX channels 33 - 40  (D/A card #5)
Kup 41 - 48   DAC address 2d0-2df DMX channels 41 - 48  (D/A card #6) 
  
You can reload DMX setup on top of your existing machine setup using 
Kuper move file "K130_DMX.mov". 

1) Save your setup in a move file, saving only necessary motor channels. 

2) Load move "K130XDMX.mov" with setup. This will overwrite all Kuper 
   channels with DMX setups,

3) Then reload your move file with setup, overwriting selected DMX channels 
   with their original configuration as motor channels with their original 
   setup.